Thursday, 23 July 2015

BCR SILVACOTE

silvacote

BITUMEN-BASED ALUMINIUM PAINT. 
silvacote is a one-pack, aluminium pigmented bitumen solution.
A general purpose reflective aluminium paint for metallic, most bituminous and concrete surfaces.
  • UV resistant.
  • Highly reflective.
  • Easy to apply.
SURFACE PREPARATION 
Any surfaces to be coated with  silvacote should be clean, mechanically sound and dry.
Steel – should be free of rust and loose material as well as oil, grease and loose paint.
Galvanised steel – should be free of loose paint, grease and in the case of new material, free of anti-white rust treatment.
Bituminous surfaces and sheet waterproofing membranes – should be free of dust, chalking and any other loose material. New bituminous surfaces should weather for 8 weeks before coating.
BONDING/PRIMING 
silvacote is normally applied directly to the surface but the following priming systems may be used where conditions so dictate.
Steel – etch primer.
Galvanised steel – no priming needed.
Bituminous surfaces – no priming needed except on ‘hungry’ sheet waterproofing membranes where a coat of prime may be applied.
MIXING 
As the aluminium pigment settles very easily silvacote must be stirred well before use, using a flat paddle. All settled material must be thoroughly dispersed. Keep silvacote well stirred during use.
TYPICAL PHYSICAL PROPERTIES OF WET MATERIAL
Density (typical)0,985 g/cm³
ColourBright aluminium
Flash point38°C
DilutionNot recommended
ConsistencyLow viscous liquid
Drying time @ 25°CTouch dry: 1 hour
Hard dry: 2 hours

TYPICAL PHYSICAL PROPERTIES DURING APPLICATION
Volume solids33%
Overcoating time @ 25°CMinimum: 2 hours
Fire resistance of wet filmInflammable
Recommend no. of coatsTwo

TYPICAL PHYSICAL PROPERTIES OF DRY FILM
Max. service tempDry 70°C
Weather resistanceWeathers well but dulls with age
ToxicityNon-toxic
Water resistanceNot recommended for immersion conditions
Solvent resistanceWill not withstand solvent spillage due to attack on bitumen
Chemical resistanceFilm (aluminium) attacked by both acids and alkalis
COVERAGE 
Steel and galvanised steel: 14 m²/1L @ 60 ?m wft
Resulting dft: 20 ?m
Bituminous surfaces: 6 – 8 m²/1L
Note: Due to the viscosity and aluminium pigments contained in silvacote this product exhibits both high spread and hiding characteristics. Low film build should, however, be avoided in the interests of longevity with due care during installation to apply the specified coating thickness.
APPLICATION 
silvacote may be applied by conventional spray or by brush or roller. On large applications it is often applied by soft broom or roofing mop. Coverage is very dependent on the porosity of the surface.
CLEANING 
Tools, brushes and mixing equipment should be cleaned immediately after use and before material has set with brush cleaner followed by washing with soap and water.
PROTECTION ON COMPLETION 
It may be necessary to apply a further coat of silvacote after three years.
TEMPERATURE AND RELATIVE HUMIDITY 
Application temperature range: 
5°C to 50°C. Do not apply if surface is less than 2°C above dew point.
MODEL SPECIFICATION 
Bituminous aluminium paint for metallic, concrete and waterproofed surfaces.
The aluminium paint will be silvacote, a one-component, aluminium reflective coating applied in accordance with the recommendations of Construction Chemicals, including bitumen prime where necessary.
PACKAGING 
1L, 5 L, 25 L, 200L containers.
HANDLING & STORAGE 
This product has a shelf life of 12 months if kept in a dry cool place in the original packaging. In more extreme conditions this period might be shortened.
HEALTH & SAFETY 
Wet silvacote is flammable and naked flames should not be allowed in the vicinity of the work area. Adequate ventilation must be provided when working in confined areas. Always wear gloves when working with the material and avoid excessive inhalation and skin contact. If material is splashed into the eye, wash with plenty of clean water and seek medical attention.
Cured silvacote is inert and harmless.
IMPORTANT NOTE 
This data sheet is issued as a guide to the use of the product(s) concerned. Whilst Construction Chemicals endeavours to ensure that any advice, recommendation, specification or information is accurate and correct, the company cannot – because has no direct or continuous control over where and how products are applied – accept any liability either directly or indirectly arising from the use of products, whether or not in accordance with any advice, specification, recommendation, or information given by the company.
FURTHER INFORMATION 
Where other products are to be used in conjunction with this material, the relevant technical data sheets should be consulted to determine total requirements. Construction Chemicals has a wealth of technical and practical experience built up over years in the company’s pursuit of excellence in building and construction technology.

No comments: